Vibration testing bangalore , Vibration analysis bangalore ,Ground vibration  bangalore , Structural vibration bangalore , Noise analysis bangalore , Dynamic balancing bangalore , Condition monitoring bangalore , Room acoustics bangalore ,Vibration testing india, Vibration analysis india, Ground vibration  india, Structural vibration india, Noise analysis india, Dynamic balancing india, Condition monitoring india, Room acoustics india ,Vibration testing , Vibration analysis,Ground vibration , Structural vibration , Noise analysis,Dynamic balancing , Condition monitoring , Room acoustics , Noise and Vibration Consultants in India , Noise and Vibration Testing Services India, Environmental Noise Testing Services India, Vibration Monitoring Services India, Ground Vibration Assessment India, Construction Vibration Monitoring India, Industrial Noise Measurement Services, Acoustic Consultant India, Metro Rail Noise and Vibration Consultant, Railway Noise and Vibration Assessment, Metro Rail Vibration Monitoring India, Ship Noise Measurement Services, IMO Noise Compliance Testing, Vibration Testing for Semiconductor, Equipment Installation, Data Centre Vibration Assessment

Structure borne noise & vibration analysis as per RDSO for Mumbai metro line-3



Mumbai Metro Rail Corporation Limited (MMRCL) retained NV Dynamics to undertake a comprehensive ground-borne noise and vibration assessment for Mumbai Metro Line 3 (Aqua Line), an approximately 33.5 km underground metro corridor in Mumbai, Maharashtra. The study was carried out to evaluate the performance of the installed High Attenuation Low Vibration track (HA-LVT) system and assess the transmission of vibration generated by train operations through the tunnel and surrounding ground to nearby sensitive receptors.

The assessment covered the entire metro corridor and included detailed screening of 15 critical receptor locations representing residential, institutional, commercial and other potentially vibration-sensitive environments. At each location, seismic-grade transducers were installed in three orthogonal directions at the ground surface and tunnel wall, while tri-axial accelerometers were mounted on the track slab to capture vibrations generated during train movement. A metro train loaded with sandbags equivalent to typical passenger loading was operated through the tunnel. Ten train passes were recorded at each location, along with background measurements in the absence of train movement.

The recorded data was processed using 1/3rd octave band analysis and evaluated against the applicable RDSO CT-38 noise and vibration criteria. Ground-borne noise levels were also estimated from the measured vibration data in accordance with the prescribed methodology.

The assessment demonstrated the effectiveness of the HA-LVT system in mitigating vibration transmission from train operations and provided a detailed evaluation of structure-borne vibration and ground-borne noise at sensitive receptor locations.



Back To Projects